Milkymist One RC2 Known Issues

From Qi-Hardware
Revision as of 09:56, 20 December 2010 by Wolfgang Spraul (Talk | contribs)
Jump to: navigation, search

Here is the known issues found during debugging and testing RC2

Major errors

  • cannot boot after fast power cycling, need to ask Xilinx FAE.
  • Production
    • parts swapped manually in wrong, must be R30 -- 4.7K ohm, R39 -- 330 ohm.
    • parts manually entered in wrong, must be R147/R148/R150 -- 4.7K ohm.
  • BoM
    • change Y2 to other stronger package.

Minor errors and improvements

These errors do not alter the functionality of the board.

  • Schematic
    • Add bigger test point for GND on top copper with circular mask to easily do some scopes.
  • PCB design
    • Put one more via on U6 pin8 and U4/U5 Vcc pins.
    • Change Y2 to a different type like Y1.
    • Placement MK1 to be more precisely.
    • Let J11 DC Jack footprint tighten to its body for better mechanical match later.
  • Materia
    • Incoming parts check: pins lifted? different mark?
  • Production/SMT
    • Notice that even incoming parts are not good, try to use AOI and manually visual inspection to cover the poor, cool and crappy soldering.
  • Testing
    • Use jtag-serial board for faster reflashing