Milkymist One RC1 Known Issues
Here is the known issues found during debugging and testting RC1.
Major errors
These errors prevent parts of the unmodified board from working. 1, Connect P[15:8] instead of P[7:0] on the video decoder chip U21, check here.
2. The installed IR detectors do not seem to work. This is not a PCB problem and it can be solved by replacing the IR detector module with one from another source. Check here
3. (To be confirmed) The MIDI optoisolator is not fast/sensitive enough. Replace it with a 6N138S. Check here.
Minor errors
These errors do not alter the functionality of the board.
- Schematic
1. Add 10K pull-down resistor on ETH_RESET_N, check here.
- PCB design
1. Add notch to mark pin 1 of J3 on silkscreen. 2. Expand a larger soldered thermal area under the pads of U10. 3. Indicate "+/- 5%" near J11 on silkscreen to let user use a DC 5V IN with +/- 5%.
- BoM
1, Use red, green and blue connectors for J18, check here.
- Production