Milkymist One Power On Off Sequence
Contents |
Normal RC2 Power On Off Sequence
Booted: A manuscript of illustrating Milkymist One RC2 0x1a board. It is collected from Milkymist One RC2 Collective Waveforms Captured While Power On/Off.
How do un-booted conditions generated?
Known bug on H/W and Solutions
Un-booted: MM1 RC2 0x2c board; CH1 = DONE(triggered source), CH2 = PROGRAM_B; triggered at rising edge by switching on an AC 110V from the input of AC(EU) DC adapter WN10B-050; without reset ic, no 82nF besides R60, power cycling : On(D2 lights flash) -> Off -> On(D2 slight lights eventually), Monitor Milkymist logo doesn't show up.
Un-booted: MM1 RC2 0x2c board; CH1 = DONE(triggered source), CH2 = PROGRAM_B; triggered at rising edge by switching on an AC 110V from the input of AC(EU) DC adapter WN10B-050; with reset ic connected to PROGRAM_B, no 82nF besides R60, power cycling : On(D2 lights flash) -> Off -> On(D2 lights off eventually), Monitor Milkymist logo shows up but doesn't enter Flicknoise control panel screen.
Booted: MM1 RC2 0x2c board; CH1 = DONE(triggered source), CH2 = PROGRAM_B; triggered at rising edge by switching on an AC 110V from the input of AC(EU) DC adapter WN10B-050; with reset ic connected to PROGRAM_B, no 82nF besides R60, power cycling : On(D2 lights flash) -> Off -> On(D2 lights off eventually), Monitor Milkymist logo shows up and enters Flicknoise control panel screen.
Un-booted: MM1 RC2 0x2c board; CH1 = DONE(triggered source), CH2 = U9 RP#; triggered at rising edge by switching on an AC 110V from the input of AC(EU) DC adapter WN10B-050; with reset ic connected to PROGRAM_B, No 82nF, power cycling : On(D2 slight flash) -> Off -> On(D2 lights On eventually), Monitor Milkymist logo shows up but doesn't enter Flicknoise control panel screen.
Booted: MM1 RC2 0x2c board; CH1 = DONE(triggered source), CH2 = U9 RP#; triggered at rising edge by switching off an AC 110V from the input of AC(EU) DC adapter WN10B-050; with reset ic connected to PROGRAM_B, no 82nF besides R60, power cycling : On(D2 lights flash) -> Off -> On(D2 lights off eventually), Monitor Milkymist logo shows up and also enters Flicknoise control panel screen.
Links
Operating Voltages of Milkymist One's Key Parts
Milkymist One RC2 Collective Waveforms Captured While Power On/Off