GPS Free Stack/Notes About Namuru

From Qi-Hardware
< GPS Free Stack
Revision as of 02:02, 12 September 2011 by 190.165.136.64 (Talk)
Jump to: navigation, search

Contents

Acknowledgments

Sampling
Accumulator interrupt signal need to be read (polling) or managed by CPU in 
order to read accumulators before they get overwrite.

Accumulators provides correlation results that can lately be interpreted/tracked to extract chips/bits once signal peak is confirmed trough acquisition.

Timing

Accumulator interrupt is asserted high according to ACCUM_COUNT value:

The Accumulator interrupt signal and flag needs to have 
between 0.5 ms and about 1 ms period.
This is to ensure that accumulation data can be read
before it is written over by new data.
The accumulators are asynchronous to each other and have a
dump period of nominally 1ms.

ACCUM_INT period = (accum_divide + 1) / 16.384MHz For 0.5 ms accumulator interrupt accum_divide = 16.384x10^6 * 0.0005 - 1 accum_divide = 0x1FFF

Accumulator interrupt MUST be asserted low after status read bit from CLEAR_STATUS register is set high.

TIC allows to sync measurements across all channels, PROG_TIC register control measurement period. 

tic period = (tic_divide + 1) * Clk period If clocked by SiGE 4162 Realmode 16.384Mhz : tic period = (tic_divide + 1) / 16.384 Mhz For default tic period (0.1s) tic_divide = 0x18ffff

Channel tracking

namuru core needs to initialize firstly the time base logic, wich will provide clock sampling for correlators and accumulators and a software driven interrupt wich means that int it only get triggered if certain registers are enabling do it so and after triggered it also need to be cleared

accumulator intterupt is enable if accumlator is enable STATUS bit 0 tic, bit 1 accumulator interrupt

both tic and interrupt int down counters can be read (may be to predict next int??)

tracking channels need to be initialiced as well:

1. loading PRN valid value 2. loading carrier NCO value initial value 3. loading code NCO value 4. loading code slew value 5. enabling tracking channel logic (epoch, slew, prn)


reset after write???? NO at same time if prn enable is logic high shifter/counter is cleared

if prn enable is logic low code generator operates (prn code generator have a shifter with no enable)

acquisition loop first we need to be certan of both noise floor threshold and code detection


Registers

(note some register are nor part of namuru upstream)

Channel related registers

Register Address Description
CH0_PRN_KEY (0x00) Gold code sequence
CH0_CARRIER_NCO (0x04) Local carrier oscilator frequency control
CH0_CODE_NCO (0x08) Local C/A code oscilator frequency control
CH0_CODE_SLEW (0x0c) C/A code delay control
CH0_I_EARLY (0x10) I Early Accumulator
CH0_Q_EARLY (0x14) Q Early Accumulator
CH0_I_PROMPT (0x18) I Prompt Accumulator
CH0_Q_PROMPT (0x1c) Q Prompt Accumulator
CH0_I_LATE (0x20) I Late Accumulator
CH0_Q_LATE (0x24) Q Late Accumulator
CH0_CARRIER_MEASUREMENT (0x28) Carrier cycle count and phase since last TIC
CH0_CODE_MEASUREMENT (0x2c) Code measurement (code half-chip, code NCO phase)
CH0_EPOCH (0x30) C/A code count latched on TIC
CH0_EPOCH_CHECK (0x34) same as EPOCH but no latched to TIC
CH0_EPOCH_LOAD (0x38) Modify epoch counter
  • epoch, slew, prn_key

Status

STATUS (0x380) bit 0 TIC occurred, bit 1 accumulator int, need to be clean manually after read
NEW_DATA (0x384) data dump one bit per channel
TIC_COUNT (0x388) Provides TIC down counter value
ACCUM_COUNT (0x38c) Provides ACCUM INT down counter value
CLEAR_STATUS (0x390) Clear STATUS flags (need to be cleared)
HW_ID (0x3bc)

Control (Mostly time-base related)

RESET (0x3c0) Software reset (need to be cleared)
PROG_TIC (0x3c4) Control TIC period value for down counter
PROG_ACCUM_INT (0x3c8) Control ACCUM INT period (must be less 1 ms)